PumpDeviceIntegrationServer
August 4, 2026 · View on GitHub
A self-contained, NativeAOT-friendly OPC UA server that demonstrates
the OPC 40223 Pumps companion specification
with a full live simulation, wired through the fluent
INodeManagerBuilder API and the additive OPC 10000-100 topology-element
builder integration.
The pump sample is the integration test for every fluent API extension
shipped under src/Opc.Ua.Server/Fluent/. Each extension is
documented in
Source-generated NodeManagers — Building richer node managers.
The simulated asset is a SimPump Corp PumpX-2000. Its nameplate,
engineering ranges, alarm trip points and simulation profile are all
published in DATASHEET.md — an official-style product
datasheet that the server is aligned to and that
tests/Opc.Ua.Di.Tests/PumpDatasheetConformanceTests.cs asserts against,
so document and address space cannot drift apart.
The simulated device
| Manufacturer / model | SimPump Corp PumpX-2000 |
| Type | Single-stage end-suction centrifugal process pump |
| Rated duty point | 25 m³/h (6.93 kg/s) at 25.5 m head (2.5 bar Δp) |
| Rated efficiency / shaft power | 72 % / 2.41 kW |
| Motor | 3.0 kW, 400 V 3~ 50 Hz, 2900 min⁻¹ |
| Units in the address space | SN-001 (Pump_1), SN-002 (Pump_2), … (--pumps N) |
| Bearing-temperature trip points | 363.15 K high, 373.15 K high-high |
| Full specification | DATASHEET.md |
Volumetric flow is the only independent variable in the simulation.
Head, differential pressure, mass flow, efficiency and shaft power all
follow from the datasheet characteristic curves
(H(Q) = 32 − 0.0104·Q², η(Q) = 72·(1 − 0.6·((Q−25)/25)²),
P = ρ·g·Q·H/η), so the published values are mutually consistent at
every tick rather than being independent sine waves.
Running the sample
cd samples/PumpDeviceIntegrationServer
dotnet run -c Release
The server listens on opc.tcp://localhost:62542/PumpDeviceIntegrationServer
by default. Override with --host localhost, --port 62550, and
--pumps N (or the matching host, port, and pumps environment
variables). --pumps defaults to 2 and accepts values from 1 to 100.
Sample console output:
info: Opc.Ua.Server.MasterNodeManager
MasterNodeManager.Startup - NodeManagers=3
info: Opc.Ua.Di.Server.DiNodeManager
Materialised OpenUSD facility (root ns=4;s=OpenUSD, PlantStage ns=1;s=OpenUSD_Stages_PlantStage).
info: Opc.Ua.Di.Server.DiNodeManager
Materialised 'Pump_1' (PumpType) under DeviceSet, NodeId=ns=1;s=5001_Pump_1.
info: Opc.Ua.Di.Server.DiNodeManager
Materialised 'Pump_2' (PumpType) under DeviceSet, NodeId=ns=1;s=5001_Pump_2.
info: Opc.Ua.Di.Server.DiNodeManager
Materialised ProductionLine (aggregates 1..n pumps).
info: Pumps.PumpNodeManager
Configuring PumpNodeManager fluent wiring...
info: Opc.Ua.Di.Server.DiNodeManager
PumpNodeManager: address space ready (10997 predefined nodes).
info: Opc.Ua.Server.Hosting.OpcUaServerHostedService
OPC UA server listening at opc.tcp://localhost:62542/PumpDeviceIntegrationServer.
Browse to Objects > DeviceSet > Pump_1 in any OPC UA client (e.g.
UaExpert) to explore the first simulated pump. BrowseNames use
identifier-safe names (Pump_1, Pump_2, ...); DisplayNames keep the
operator-friendly labels (Pump #1, Pump #2, ...). Pass --pumps N
or set pumps=N to materialise more instances. Every pump is wired
through the same simulation, alarm, history, identification, maintenance,
and declarative DI ConfigureDevicesFor flow, so pumps added after
startup automatically join the same live simulation. All pumps are units
of the same PumpX-2000 product and differ only in serial number, asset
id, component name and installation bay. They publish monitored data
changes every 250 ms, with deterministic phase offsets so their values do
not move in lockstep.
Subscribe to the EventNotifier attribute on any pump to receive alarm
condition events when its simulated MotorOverheat state activates or
clears. Each pump is also registered as a root notifier, so the same events
are available from a subscription on the Server object.
Address space
flowchart TD
Objects["Objects"]
DeviceSet["DeviceSet<br/><i>OPC 10000-100 (DI)</i>"]
P1["Pump_1 · SN-001<br/><i>PumpType, DisplayName 'Pump #1'</i>"]
P2["Pump_2 · SN-002<br/><i>PumpType, DisplayName 'Pump #2'</i>"]
Id["Identification<br/><i>21 nameplate properties</i>"]
Op["Operational<br/><i>OPC 40001-1 (Machinery)</i>"]
Meas["Measurements"]
Ev["Events<br/><i>EventNotifier</i>"]
Maint["Maintenance<br/>└ GeneralMaintenance"]
Diag["Diagnostics<br/><i>ad-hoc FunctionalGroup</i>"]
Usd["OpenUsdRepresentation<br/><i>twin bindings + ShaftAngle</i>"]
Vals["DifferentialPressure · FluidTemperature<br/>BearingTemperature · PumpPowerInput<br/>MassFlow · PumpEfficiency · Level<br/>NumberOfStarts"]
Alarm["OverTempAlarm<br/><i>NonExclusiveLimitAlarmType</i>"]
SupF["SupervisionProcessFluid<br/>└ Cavitation"]
SupP["SupervisionPumpOperation<br/>└ MotorOverheat"]
Objects -->|Organizes| DeviceSet
DeviceSet -->|Organizes| P1
DeviceSet -->|Organizes| P2
P1 -->|HasComponent| Id
P1 -->|HasComponent| Op
P1 -->|HasComponent| Ev
P1 -->|HasComponent| Maint
P1 -->|HasComponent| Diag
P1 -->|HasComponent| Usd
Op -->|HasComponent| Meas
Meas --> Vals
Ev -->|HasComponent| Alarm
Ev -->|HasComponent| SupF
Ev -->|HasComponent| SupP
P1 -.->|HasNotifier| Ev
Alarm -.->|SourceNode| Vals
Vals -.->|bound signals| Usd
Only the subtree of Pump_1 is drawn; every further pump (Pump_2, …,
up to --pumps N) carries an identical one. Diagnostics is the one
group that is not part of the model — it is added declaratively per pump
by the non-typed WithFunctionalGroup(QualifiedName, ...) overload from
Program.cs. OpenUsdRepresentation carries the twin bindings described
in The OpenUSD twin.
Startup and hosting flow
sequenceDiagram
participant Host as HostApplicationBuilder
participant DI as AddOpcUa().AddServer()
participant Factory as PumpNodeManagerFactory
participant NM as PumpNodeManager
participant Runner as IDiPostSetupRunner
Host->>DI: Configure<PumpDeviceIntegrationOptions>(--pumps N)
Host->>DI: AddNodeManager<PumpNodeManagerFactory>()
Host->>DI: ConfigureDevicesFor<PumpNodeManager>(...)
DI->>Factory: CreateAsync(server, configuration)
Factory->>NM: new PumpNodeManager(.., postSetupRunner, options)
NM->>NM: LoadPredefinedNodesAsync<br/>AddOpcUaDi + Machinery + Pumps
NM->>NM: OnAddressSpaceReadyAsync
loop for each of N pumps
NM->>NM: ConfigureInstancesAsync → Pump_n (PumpType)
NM->>NM: MaterialiseNameplate + optional children
end
NM->>NM: CreateFluentBuilder().Configure(Configure).Seal()
Note over NM: Configure wires identification, maintenance,<br/>measurements, alarms and history per pump
Note over NM: Seal starts the 250 ms simulation loop
NM->>Runner: post-setup pipeline
Runner->>NM: TopologyElement(pumpNodeId).WithFunctionalGroup("Diagnostics")
Simulation and alarm dataflow
flowchart LR
Tick(["250 ms tick<br/>builder.Simulation(...)"])
Adv["AdvanceSimulation()"]
Sim["PumpSimulationState.Publish<br/><i>per pump, phase offset 17 ticks</i>"]
Curves["Datasheet curves<br/>H(Q) · η(Q) · P = ρgQH/η"]
Upd["IValueUpdater<T>.SetValue"]
Vars["Measurement variables<br/><i>EURange + EngineeringUnits</i>"]
MI["MonitoredItems<br/><i>client subscriptions</i>"]
Ovr["MotorOverheat<br/><i>≥ 363.15 K, hysteresis 361.15 K</i>"]
Cav["Cavitation<br/><i>level < 2.10 m, hysteresis 2.20 m</i>"]
Alarm["OverTempAlarm<br/><i>ActivatesAlarm edge tracker</i>"]
Notif["HasNotifier chain<br/>Pump → Server object"]
Ev(["Condition events"])
Shaft["ShaftAngle<br/><i>∫ speed dt, speed ∝ ṁ / ṁ rated</i>"]
Usd(["OpenUSD twin bindings"])
Tick --> Adv --> Sim --> Curves --> Upd --> Vars --> MI
Sim --> Ovr --> Alarm --> Notif --> Ev
Sim --> Cav --> Vars
Vars -.->|SourceNode| Alarm
Curves --> Shaft --> Usd
Vars -.->|bound signals| Usd
Validating the address space
The
Pump Address Space Validation
workflow runs nightly and can also be started manually. It builds this sample,
installs the latest stable
OpcUaAddressSpaceChecker
global tool, and validates all PumpType instances.
To reproduce the validation locally, start the server and run the following commands in another terminal:
dotnet tool install --global OpcUaAddressSpaceChecker
opcua-check-address-space `
--endpoint opc.tcp://localhost:62542/PumpDeviceIntegrationServer `
--type "nsu=http://opcfoundation.org/UA/Pumps/;i=1052" `
--severity-threshold warning `
--view-completeness complete `
--require-complete-view
The nightly check keeps the tool's default auto validation-view policy and
fails on confirmed errors or any checker execution failure.
The OpenUSD twin
The server also publishes an OpenUSD representation of the pump line
(the draft OPC UA — OpenUSD Bindings companion model, see
docs/OpenUsd.md) and serves its USD layers as
embedded assets, so a connector can render the twin with no external
asset resolver.
Every configured pump is a twin in its own right. The DeviceSet
carries a plant-level representation anchored on /Plant whose single
Many component binding is scoped to PumpType, so a connector composes
one @pump.usda@</Pump> reference prim per pump — /Plant/Pumps/Pump_1,
/Plant/Pumps/Pump_2, … — and each pump's own bindings drive only its own
prim. Start the server with --pumps 6 and six fully modelled machines
appear, each turning at its own speed, each with its own gauges, fluid
level and alarm halos. Each pump publishes its bay as a
ThreeDCartesianCoordinates value bound to xformOp:translate, which is
what lays them out in a row without the stage having to author anything
per pump.
The composition arc is Reference, not Instance: an instanceable prim
turns its descendants into a shared prototype, and a shared prototype
cannot carry the per-pump impeller rotation, casing colour or needle
positions that make each machine read as its own.
Assets/Plant.usda models the pump as a real machine: a horizontal
long-coupled end-suction centrifugal pump built to EN 733 (formerly
DIN 24255), size 65-200, following the published dimensions of the
Grundfos NK 65-200 / KSB Etanorm 65-200 family and driven by an
IEC 160M motor on a fabricated baseplate.
| Item | Value |
|---|---|
| Baseplate | 1.80 × 0.46 × 0.12 m |
| Shaft centreline above baseplate | 0.160 m (the IEC 160M frame number is the shaft height) |
| Volute casing | 0.355 m outer diameter × 0.110 m wide |
| Suction flange | DN80 axial, OD 0.200 m (EN 1092-2 PN16) |
| Discharge flange | DN65 vertical, OD 0.185 m (EN 1092-2 PN16) |
| Impeller | 0.198 m, six backward-curved vanes |
| Motor frame | 0.254 m outer diameter × 0.615 m long |
| Bay pitch | 2.4 m |
Livery is KSB signal blue (RAL 5005) for the wetted castings and
RAL 7035 light grey for the motor. pump.usda is that machine as a
self-contained component asset, referenced once per configured pump. It is
generated from the /Plant/Pumps/P101 master by
Assets/generate_pump_assets.py — edit the master and re-run the
generator, never the generated layer. The master itself is authored
active = false, because the composed pumps are what render.
Two departures from a real pump are deliberate, so the twin can be seen: the suction pipe is drawn as a stub leaving the casing eye open (a cutaway, as trade-show display pumps are presented) and the coupling guard is a cage rather than a solid barrel. Both let you watch the shaft turn.
The hall
The rendered hall holds exactly the pumps the connected server simulates —
one referenced pump.usda prim per configured pump, one bay every 2.4 m along
+Y, each with its suction vessel behind it. Nothing else is drawn: the
ProductionLine aggregation and the cross-server component are address-space
topology, not machines anyone is driving, so composing them put pumps in the
twin that no client could account for, and a pump federated from another
server is not this server's to show at all.
HeroCamera is an operator's viewpoint: eye height 1.65 m in the aisle on the
discharge side, pitched 7° below horizontal, framing every configured pump at a
three-quarter angle with the vessels behind them. The framing holds from one
pump up to eight, so it does not have to be retuned for --pumps N. Pass
--camera /Plant/HeroCamera to start on it.
An error draws a red circle on the floor around the machine. A ring reads
from anywhere in the hall and from any camera angle; a lamp on a mast only reads
when you happen to be looking straight at it. The ring says that a pump is in
alarm; the two fault halos — at the suction eye for cavitation, on the bearing
bracket for motor overheat — say why. All three are authored invisible and
only a live supervision binding reveals them, so a machine nothing is bound to
never shows an alarm it did not raise.
Live bindings
All paths are relative to the pump's own prim, so every pump drives its own copy of every target.
| Source | USD target | Effect |
|---|---|---|
BayPosition | xformOp:translate | places the pump in its bay |
ShaftAngle | …/Impeller.xformOp:rotateZ | turns the shaft, impeller and coupling |
ShaftAngle | …/Motor/FanBlades.xformOp:rotateZ | motor cooling fan |
BearingTemperature | …/Body/Mat/Surface.inputs:diffuseColor | casing colour, blue (cool) → red (hot) |
BearingTemperature | …/PowerEnd/TempGauge/Needle.xformOp:rotateZ | bearing-temperature gauge |
DifferentialPressure | …/Discharge/Gauge/Needle.xformOp:rotateZ | discharge pressure gauge |
FluidSurfacePosition | …/SuctionVessel/Surface.xformOp:translate | liquid surface rides on the published Level |
FluidTemperature | …/Suction/Neck/Mat/Surface.inputs:diffuseColor | suction line tint |
MassFlow, PumpEfficiency, NumberOfStarts | …/Motor/Nameplate.inputs:* | readouts a viewer shows on selection |
| any supervision alarm | …/AlarmRing.visibility | red circle on the floor around the machine |
Cavitation | …/Suction/CavitationHalo.visibility | cavitation, at the suction eye where the fault is |
MotorOverheat | …/OverheatHalo.visibility | overheat, on the bearing bracket |
SpeedSetpoint | …/Impeller.inputs:speedSetpoint | opt-in UsdToUaCommand, fail-closed |
MassFlow is a rate, so binding it straight to a rotation op pins the
shaft at a fraction of a degree and the pump looks dead. The simulation
integrates the running speed into a ShaftAngle instead, and the binding
scales it down to a legible ~45°/s — a real 2900 rpm shaft would alias
into a stroboscopic blur at any practical sampling rate. Speed follows
flow, so the impeller visibly slows and picks up with the duty point, and
the phase offset the simulation gives each pump means no two shafts are
ever at the same angle.
The OverTempAlarm condition itself is deliberately not bound. The
fluent alarm builder leaves the condition's state children on their
standard namespace-0 declaration NodeIds — which
PumpInstanceNodeIdRegressionTests pins — so every pump's alarm shares
one ActiveState, Severity and AckedState node, and binding those
would ring every pump in the hall at once. The per-pump supervision
states are the alarm indication instead: they are genuinely per instance,
and they are what drives the condition through ActivatesAlarm in the
first place.
A real pump shaft is horizontal, but the binding contract fixes the
driven operation as xformOp:rotateZ. Impeller therefore carries a
static xformOp:rotateY = 90 ahead of xformOp:rotateZ in
xformOpOrder, which lays its local Z along the world shaft axis. The
impeller and the coupling both hang off that one rotating prim, so they
turn together — as they do on the real machine. The gauge needles use the
same trick with xformOp:rotateX = 90, because their dials face the
plant Y axis.
Which op a bound prim has to declare depends on the render target, and
getting it wrong fails silently. A connector accumulates Translation,
Rotation and Scale into a single xformOp:transform matrix, so
that it never has to rewrite xformOpOrder — the list is uniform, and
an opinion in the asset layer cannot be cleared from the stronger layer a
connector edits. Every other xformOp: property, such as the scalar
xformOp:rotateZ above, is authored under its own name. USD evaluates
only the ops named in xformOpOrder, so a prim bound to a Translation
target must declare xformOp:transform — the pump root and the suction
vessel's fluid surface both do. Naming xformOp:translate there instead
makes USD discard every value written to it: the pumps keep reporting
their bay positions over OPC UA, and every one of them renders on the
origin, so the hall looks like it holds a single machine.
TransformBindingsTargetDeclaredXformOpsAsync checks each transform
binding against the op the served asset actually declares.
Because the render targets expect degrees Celsius and bar while OPC
40223 publishes Kelvin and Pascal, the colour bindings declare the
conversion themselves (offset: -273.15 and scale: 1e-5); §5.8
applies Scale then Offset. The gauge scales are derived from the
PumpDatasheet engineering ranges, so a datasheet change moves the
needles with it. PumpEfficiency is a readout rather than a colour: the
DisplayColor ramp models a temperature, and colouring efficiency with
it would read as a lie.
Viewing it
Run the server, then point the connector at it with --view:
Opc.Ua.OpenUsd.Connector --server opc.tcp://localhost:62542/PumpDeviceIntegrationServer `
--insecure --view --fetch-assets .\stage-cache
The connector fetches the server-delivered layers, composes a
self-contained stage and streams the live OPC UA values into
live.usda and the viewport. See
tools/Opc.Ua.OpenUsd.Connector.
Running in Docker
A Dockerfile is provided that builds the Release
publish output on the .NET AzureLinux 3 base images and runs it as a
non-root user.
Build from the repository root, not from this folder. The image needs the full source tree (
src/,samples/,tools/), so the Docker build context must be the repo root and the Dockerfile is selected with-f. Runningdocker build .from inside this folder fails fast with a message telling you the correct command.
# from the repository root:
docker build -f samples/PumpDeviceIntegrationServer/Dockerfile `
-t pumpdeviceintegrationserver:local .
Run it, publishing the OPC UA port:
docker run --rm -p 62542:62542 pumpdeviceintegrationserver:local
Inside the container the endpoint binds to 0.0.0.0 so it is reachable
from the host. Override the bind host and port via environment variables:
docker run --rm -p 62550:62550 `
-e host=0.0.0.0 -e port=62550 -e pumps=4 `
pumpdeviceintegrationserver:local
The server creates its certificate/PKI store under /app at runtime.
To persist certificates across container restarts, mount a volume:
docker run --rm -p 62542:62542 `
-v pump-pki:/app/pki `
pumpdeviceintegrationserver:local
The image is built and published to the GitHub Container Registry by the
pump-device-integration-server-docker.yml
workflow on every push to master and on manual dispatch.
What the sample demonstrates
| Feature | Where |
|---|---|
AddOpcUa().AddServer(...).AddNodeManager<T>() hosting | Program.cs |
| Multi-model composition (DI library + locally source-generated Machinery + Pumps) | PumpNodeManager.cs LoadPredefinedNodesAsync |
Optional nameplate materialisation via generator-emitted AddXxx(context) helpers across three namespaces (DI / Machinery / Pumps) | PumpNodeManager.cs MaterialiseNameplate |
Identification properties via WithProperty(name, value) | PumpNodeManager.Configure.cs WithIdentification |
Optional-child materialisation via generator-emitted AddXxx(context) helpers (Operational / Measurements / Events / SupervisionProcessFluid / SupervisionPumpOperation / Maintenance) | PumpNodeManager.cs MaterialisePumpOptionalChildren |
Engineering units / EURange via WithEngineeringUnits / WithEURange | CreatePumpSimulation |
Push-style monitored value updates via Bind(out IValueUpdater<T>) | CreatePumpSimulation |
Discrete NumberOfStarts counter published on change | CreatePumpSimulation |
| One 250 ms simulation tick for all phase-shifted pumps | Configure → AdvanceSimulation |
| Datasheet-driven simulation (one independent variable, derived values) | PumpDatasheet.cs + PumpSimulationState.Publish |
Browsable/subscribable limit alarm with thresholds and acknowledge handler via CreateLimitAlarm(...).WithLimits(...).MonitorVariable(...) | CreatePumpSimulation |
Boolean supervision (TwoStateDiscreteState) → alarm activation, condition raise/clear, and reported events via .ActivatesAlarm(...) | CreatePumpSimulation |
EventNotifier, HasNotifier, and HasEventSource instance wiring | PumpNodeManager.cs + fluent alarm builders |
| Cross-namespace path resolution (Pump_1 in Pumps NS → Operational in Machinery NS → Measurements in Pumps NS, all in one unqualified browse path) | src/Opc.Ua.Server/Fluent/BrowsePathResolver.cs |
Declarative ConfigureDevicesFor topology-element configuration adding an application-namespace Diagnostics functional group to every generated PumpType instance | Program.cs |
| In-memory historian wiring so NodeSet-declared historical access is genuinely serviceable for all analog measurements and historized supervision booleans | PumpNodeManager.Configure.cs UseHistorian() / Historize() |
One OpenUSD twin per configured pump: per-pump prim, signals and bindings, composed from one component asset by a Many component binding | OpenUsdRepresentation.cs + OpenUsdComposition.cs |
Architecture
PumpDeviceIntegrationServer/
├── Program.cs # AddOpcUa().AddServer(...).AddNodeManager<T>()
│ # + ConfigureDevicesFor diagnostics for every pump
├── PumpNodeManager.cs # Hand-written FluentNodeManagerBase
│ # + LoadPredefinedNodesAsync (multi-model)
│ # + CreateAddressSpaceAsync (builder setup)
├── PumpNodeManager.Configure.cs # partial — fluent wiring + simulation tick
├── OpenUsdRepresentation.cs # partial — one twin per pump: prim path,
│ # signal Variables and live bindings
├── OpenUsdComposition.cs # partial — plant aggregation (one prim per
│ # configured pump) + ProductionLine demo
├── PumpDatasheet.cs # DATASHEET.md as compile-time constants
├── DATASHEET.md # official-style PumpX-2000 product datasheet
├── PumpDeviceIntegrationServer.csproj # ProjectReference to Opc.Ua.Di model lib
│ # AdditionalFiles for Machinery + Pumps
│ # NodeSet2 (consumed by source generator)
├── Assets/
│ ├── Plant.usda # stage master (P101 is the authoring
│ │ # master, deactivated so only the
│ │ # composed pumps render)
│ ├── pump.usda # generated component asset, one per pump
│ └── generate_pump_assets.py # regenerates it from the P101 master
├── Model/
│ ├── Opc.Ua.Machinery.NodeSet2.xml # AdditionalFiles — build-time only
│ └── Opc.Ua.Pumps.NodeSet2.xml # AdditionalFiles — build-time only
└── Properties/AssemblyInfo.cs
The Opc.Ua.Di model library is consumed as a project reference (its
types live under the Opc.Ua.Di namespace and are source-generated
from the ModelDesign XML). Cross-namespace references from Machinery
and Pumps to DI types resolve through the
[assembly: ModelDependencyAttribute] carried in the Opc.Ua.Di
assembly — no DI NodeSet2 XML needed in this project. The unified
attribute carries the compact type-table payload that the consumer's
source generator imports at compile time; see
ModelDependencies.md for the wire
format and consumer-side flow.
The Machinery and Pumps NodeSet2 XMLs are source-generated locally
inside this assembly via the <AdditionalFiles> plumbing in the
.csproj. The generator emits typed *State classes, NodeId tables,
and the AddOpcUaMachinery / AddOpcUaPumps extension methods that
LoadPredefinedNodesAsync calls. No runtime XML loading happens — the
Model/ folder is a build-time input only. Consumer assemblies that
want to reference Machinery or Pumps the same way they reference
Opc.Ua.Di should source-generate against the model XML inside their
own assembly using the same <AdditionalFiles> pattern.
The sample intentionally does not add GeneratesEvent to pump instances.
OPC 10000-3 restricts that reference to ObjectType, VariableType, and Method
declarations; runtime delivery is provided by the notifier/event-source
hierarchy and ReportEvent.
Extending the sample
When you change a published value, update
DATASHEET.mdand the constants inPumpDatasheet.cstogether —PumpDatasheetConformanceTestsfails the build otherwise.
- Add a measurement: open
PumpNodeManager.Configure.cs, add a bound updater inCreatePumpSimulation, store it inPumpSimulationState, and publish its value fromPublish. Add its engineering range toPumpDatasheet.Rangesand to section 4 of the datasheet. - Add an alarm: create it from the typed
Eventsbuilder inCreatePumpSimulationand wire the triggering boolean variable via.ActivatesAlarm(...). Document its trip points in section 7 of the datasheet. - Add a nameplate field: materialise it with the generator-emitted
AddXxx(context)helper inPumpNodeManager.MaterialiseNameplate, assign its value inWithIdentification, and add the row to section 2 of the datasheet. - Add pumps: pass
--pumps N(or setpumps=N) to materialise N identical simulatedPumpTypeinstances.PumpNodeManagerdemonstrates the hand-written fluent style by creating every pump, wiring Identification, Measurements, Supervision, Maintenance, engineering units, alarms, history, and the simulation callbacks.Program.cskeeps the declarative DI style by wrapping each generated pump withctx.TopologyElement<PumpState>(...)and adding the ad-hoc Diagnostics functional group throughConfigureDevicesFor<PumpNodeManager>.CreatePumpAsyncregisters each new instance with the shared simulation, so pumps created after startup join the same live tick.
NativeAOT publishing
cd samples/PumpDeviceIntegrationServer
dotnet publish -c Release -r win-x64
The pump server publishes cleanly under NativeAOT — no trim or AOT warnings — because every fluent extension is reflection-free and the generated model factories are statically rooted.
See also
DATASHEET.md— the official-style PumpX-2000 product datasheet the simulation implements.docs/DeviceIntegration.md— full developer guide for the DI library trio (device builder, hosting integration, lock service, software-update package store, client helpers).