This document is normative: every numeric field in the MAS schema carries the unit listed here. JSON values are bare numbers; the unit is fixed by this table and is not encoded per value. Tools may render values in scaled units (e.g. mm, kHz, °F) for human display, but the wire format is what this document specifies.
The ratifying specification is RFC 0001 v2
(proposals/0001-units.md). For the rationale on why MAS does not wrap
values in {value, unit} objects, see that RFC.
Quick reference
| Quantity | Unit | UCUM code | Typical fields |
|---|---|---|---|
| Frequency | hertz | Hz | switchingFrequency, ringing frequency, resonance |
| Time | second | s | dwell time, duty-cycle interval |
| Temperature | degree Celsius | Cel | ambientTemperature, Curie temperature, insulation class, loss-curve x-axes |
| Temperature difference | kelvin | K | temperature rise, thermal resistance numerator |
| Length | metre | m | core dimensions, gap length, winding window dims |
| Area | square metre | m2 | effective area Ae, window area Aw |
| Volume | cubic metre | m3 | effective volume Ve |
| Mass | kilogram | kg | core mass, winding mass |
| Current | ampere | A | DC, peak, RMS (per field name) |
| Voltage | volt | V | DC, peak, RMS (per field name) |
| Resistance | ohm | Ohm | DC resistance, AC effective |
| Inductance | henry | H | self, mutual, leakage |
| Capacitance | farad | F | inter-winding, stray |
| Charge | coulomb | C | partial-discharge inception |
| Energy | joule | J | per-cycle, stored |
| Power | watt | W | losses, throughput |
| Loss density | watt per cubic metre | W/m3 | core-loss curve y-axis |
| Magnetic flux density | tesla | T | peak, AC, saturation |
| Magnetic field strength | ampere per metre | A/m | H, coercive force Hc |
| Magnetic flux | weber | Wb | Φ |
| Magnetic permeability | dimensionless (relative) | 1 | μᵣ; absolute μ is rarely used |
| Reluctance | per henry | /H | core, gap |
| Thermal resistance | kelvin per watt | K/W | rise per loss |
| Thermal conductivity | watt per metre kelvin | W/(m.K) | bobbin / potting / core property |
| Specific heat capacity | joule per kilogram kelvin | J/(kg.K) | thermal mass |
| Density (mass) | kilogram per cubic metre | kg/m3 | material density |
| Resistivity | ohm metre | Ohm.m | wire material |
| Conductivity | siemens per metre | S/m | wire material (alternate to resistivity) |
| Angle | radian | rad | phase, mechanical angle |
| Plane angle (catalogue) | degree | deg | only where the catalogue source specifies degrees; document at the field |
| Dimensionless ratios | dimensionless | 1 | duty cycle, turns ratio, winding fill factor |
Conventions
Temperature is Celsius
MAS uses °C for every temperature field. Rationale:
- Every ferrite datasheet, every wire enamel temperature class (IEC 60085: B = 130 °C, F = 155 °C, H = 180 °C, etc.), every Curie point, every insulation rating is published in °C.
- ISO 80000-5 explicitly accepts °C alongside K and recommends °C for "everyday temperatures."
- IEC standards in the magnetics space (60085, 60401, 62317, 63093) use °C.
Exception: temperature differences (rise above ambient, the
denominator inside thermal resistance) use K. A Celsius difference
and a Kelvin difference are numerically identical, but K is the SI form
for differences. Field names that mean a difference (e.g.
temperatureRise, K/W thermal resistance) are in K.
Length is metres
JSON values for length, area and volume are in base SI (m, m², m³).
A core leg of 34.1 mm is encoded as 0.0341. Catalogue UIs typically
display millimetres; that is a presentation choice, not a schema one.
RMS, peak and DC
Field names always disambiguate: rmsCurrent, peakCurrent,
dcCurrent. A bare current (without a qualifier) is a documentation
defect — open an issue.
Single numbers, not tolerance bands
Datasheet values are encoded as single numbers. Permeability, saturation
flux density, gap length, resistivity — one nominal value per field, no
{nominal, minimum, maximum} wrapper. If a future field genuinely needs
a band, sibling fields (<field>Min, <field>Max) are added at that
point.
Out-of-table units
If you encounter a numeric field whose unit is not covered here, that is a bug in either the spec or this document — please open an issue. Do not silently introduce a new unit in a downstream tool.
UCUM
The UCUM codes in the third column are informative, included so that downstream consumers (HL7 FHIR exporters, AAS / Industry 4.0 digital twins, IEC 61360 / CDD records) can carry MAS data lossless. They are not currently encoded in the JSON. RFC 0001 v2 §3 discusses why.